Home / Products / Insulated Pipe Series / Pre-Insulated Steel Pipe
Pre-Insulated Steel Pipe

Heat is expensive. Keep it in the pipe.

Working pipe + rigid polyurethane foam + HDPE casing, plus steel-jacket steam pipe and overhead mineral-wool composite for higher temperatures. Structures selected by medium temperature, not by habit.

Anatomy of one insulated pipe

Four layers, four jobs — and one of them is usually skipped

01 / Carrier

Steel carrier pipe

Spiral, ERW or seamless, hydro-tested before foaming. Wall thickness set by design pressure, not by the foam.

02 / Insulation

Rigid PU foam

Density ≥ 60 kg/m³, closed-cell ≥ 88%, poured in the cavity and bonded to both walls so the three layers act as one.

03 / Casing

HDPE outer casing

Waterproof and abrasion-resistant; the only barrier between the foam and groundwater. Damaged casing equals wet foam equals no insulation.

04 / Monitoring

Leak-detection wire

Optional but strongly advised: a wire run inside the foam turns an invisible leak into a located point on a monitor.

What it looks like cut open

Judge a pre-insulated pipe by its cross-section

Cut a sample and look at three things: foam cells — fine and uniform means the pour was right; foam-to-steel bond — it should tear, not peel off clean; casing wall — even thickness all round, no ovality from storage.

We pour on a tilting platform so the foam fills the annulus evenly along the whole length — the end where the pipe was standing still is where bad insulation shows up first.

Buying tips
1) Ask for the foam density and closed-cell test report, not just the pipe certificate. 2) Check casing grade (PE80/PE100) and wall thickness against GB/T 29047. 3) Require the joint procedure and the same batch of foam chemicals for field joints.
INSULATION
Heat loss, in numbers

What 50 mm of foam actually buys you

Indicative figures for a buried hot-water line (soil 5 °C, 90 °C medium). Actual results depend on burial depth, soil moisture and joint quality — we calculate per project on request.

Nominal dia. Bare pipe loss (W/m) With 50 mm PU (W/m) Reduction Temperature drop per km
DN200≈ 210≈ 19≈ 91%0.6 – 0.9 °C
DN500≈ 290≈ 24≈ 92%0.3 – 0.5 °C
DN800≈ 360≈ 29≈ 92%0.15 – 0.25 °C
DN1200≈ 430≈ 34≈ 92%0.08 – 0.15 °C

Rule of thumb: the larger the diameter, the less each kilometre costs you in temperature — and the more the joints matter.

Select by temperature

Three temperature bands, three structures

≤ 120 ℃Hot water, DH networks
Direct-buried PU foam with HDPE casing, to GB/T 29047 / CJJ/T 81. The workhorse of district heating: cheapest per metre, fastest to lay, no trench needed. Working pipe usually spiral or ERW.
120 – 350 ℃Steam, high-temp water
Steel-jacket steam pipe (钢套钢): carrier pipe + microporous calcium silicate or aluminium silicate + stainless steel reflection layer + outer steel jacket, with fixed and sliding supports inside. Expansion is handled by the structure, not by the soil. To GB/T 28638.
> 350 ℃High-temperature runs, overhead lines
Overhead mineral-wool / aluminium-silicate composite: layered blankets with stainless-steel banding and a metal cladding on top, so the insulation is serviceable and repairable for the life of the line. Used on steam mains, process lines and plant racks where sections can be opened for valve maintenance.
The three structures, on the floor

Same yard, three different builds

Direct-buried PU

HDPE casing + rigid foam + carrier. Stored outdoors, laid straight into the trench.

PU

Steel-jacket steam pipe

Outer steel jacket carries the load and the expansion; inner supports keep the carrier centred.

STEEL JACKET

Overhead mineral-wool composite

Layered wool or aluminium silicate with cladding — repairable, for steam mains and plant racks.

WOOL
Spray-and-wrap process

Spray-and-wrap insulated steel pipe — five steps, none skipped

Large-diameter insulated pipe uses the spray-and-wrap process: the steel pipe rotates while polyurethane is sprayed on layer by layer, then the jacket is wound on continuously — no pre-made casing, insulation and jacket formed as one piece. Skip a step here and it shows up years later as a cracked jacket, water ingress and rising heat loss.

1

Carrier inspection & shot blasting

Heat number and mill certificate checked first, NDT re-verified, then full shot blasting. A poor surface means the foam will not bond — and you get voids later.

Sa2.5 · 40–80 μm anchor profile
2

Polyurethane spray · layer by layer

The pipe rotates at constant speed while mixed polyurethane is sprayed on pass after pass. Layer thickness and density are controlled online with no delamination; insulation thickness is freely adjustable, not limited by any casing size.

Layer-by-layer spray · density ≥60 kg/m³
3

Wound jacket · one-piece forming

While the foam is still fresh, PE (or FRP) tape is heated and spiral-wound over the insulation, laps fusion-bonded into a continuous seamless jacket locked to the insulation layer.

Fusion-bonded laps · seamless jacket
4

End sealing

Waterproof caps or heat-shrink sleeves on both ends, sealant on the end face. Open ends are what kills pipes in storage and sea freight.

100% end sealing
5

Final test & marking

Holiday test on the casing, dimensional re-check, continuity test on the detection wire; specification and heat number marked on the pipe.

15 kV holiday test

Process control points

Thermal conductivity≤0.033 W/(m·K)
Foam density≥60 kg/m³
Closed-cell ratio≥88%
Casing thicknessper GB/T 29047
Detection wirecontinuity 100%
Pressure testper contract
Field joints

The pipe is factory work. The joint is field work. Guess which one fails.

1

Cut back cleanly

Casing cut square, foam removed to the exact welding length, end faces dry and dust-free.

2

Weld and test the carrier

Carrier welded to the qualified WPS, NDT on the joint, pressure test before anything is closed up.

3

Pour the foam

Same chemical system as the plant, injected in one shot, density and fill checked at the joint.

4

Seal the casing

Heat-shrink sleeve or electrofusion band, overlap to spec, then a holiday test on the finished joint.

We would rather tell you this plainly: a 10 km line has 800–900 joints, and every one of them is a hole waiting to happen if the procedure is skipped. That is why we supply the joint kit, the procedure card and — if you want — the crew.

JOINT

A leak you can find without digging

Two tinned copper wires run the whole length inside the foam. Water reaching them changes the loop resistance; the monitor converts that into a distance reading, so the repair crew opens one pit instead of ten.

Recommended for trunk mains, river and road crossings, and any section where excavation is expensive. Wire type, loop layout and monitor brand are agreed at design stage.

± 1 mTypical fault location accuracy
0Extra trench metres to find a leak
One pitInstead of a section excavation
Specifications

Pre-insulated pipe specification

StandardsGB/T 29047 · CJJ/T 81 · GB/T 28638 · SY/T 0415 · GB 50264
StructuresDirect-buried PU · steel-jacket steam · overhead mineral wool / aluminium silicate
DiameterCarrier DN15 – DN1400 · casing up to Φ1500
FoamRigid PU, density ≥ 60 kg/m³, closed cell ≥ 88%, compressive strength ≥ 0.3 MPa
CasingHDPE PE80 / PE100, wall thickness to GB/T 29047
Service temperaturePU ≤ 120 °C · steel jacket 120–350 °C · mineral wool ≥ 350 °C (overhead)
JointsField pour + heat-shrink sleeve / electrofusion band / welded steel jacket
OptionsLeak-detection wire · warning tape · end seals · prefabricated bends and tees
InspectionFoam density and closed cell · bond strength · casing thickness · hydrostatic test on carrier
FAQ

Three questions engineers ask us

Direct burial or pipe trench?

Direct burial saves the trench civil works, is faster and takes less land — the mainstream for district heating. A trench is easier to inspect but costs more and needs drainage. Use a trench where the water table is high, the soil is soft, or frequent access is required; direct-bury the rest.

Is the leak-detection wire worth it?

For trunk mains, crossings and access-restricted sections, yes — it turns an invisible leak into a located point. For short internal runs where excavation is cheap, it can be skipped.

Who makes the joints?

Best: our crew, or yours following our procedure card with our kit. The joint is the weakest link — wrong foam ratio or a sleeve overlap 20 mm short is enough to flood a whole section.

Tell us the medium and the color

Technical proposal and quotation within one working day.