National service hotline +86 192 0128 3418
Puwa Industrial Park, Yanshan Economic Development Zone, Hebei
Home / Products / Coated Pipe Series / Fusion-Bonded Coated Pipe
Anti-Corrosion Coated Steel Pipe

Six anti-corrosion processes on one line — 200,000 ㎡ a year, up to DN3800

Outer coating isolates the pipe from soil, water and chemicals; inner lining resists the conveyed medium — to GB/T 23257, SY/T 0413 and DIN 30670, on spiral substrates up to DN3800 in the same factory.

Anti-corrosion · 3PE

3PE three-layer anti-corrosion — first choice for trunk mains

Fusion-bonded epoxy + copolymer adhesive + polyethylene, formed in one pass: the epoxy base supplies adhesion and cathodic-disbondment resistance, the adhesive fuses epoxy and PE into one body, and the PE top coat takes mechanical impact and soil stress. To GB/T 23257 and DIN 30670; thickness normal ≥2.5 mm, reinforced ≥2.9 mm, extra-heavy ≥3.7 mm.

Where it goes: long-distance oil, gas and water trunk lines, rocky mountain sections, river crossings, saline high-resistivity soils; with cathodic protection the design life exceeds 30 years, and every pipe passes spark holiday detection before shipment.

Buying tips
1) Choose normal/reinforced/extra-heavy grade by soil corrosivity and project class; 2) pair trunk lines with PSL2 SSAW substrate; 3) field joints use heat-shrink sleeves matched to the line coating.
ANTI-CORROSION
Anti-corrosion · TPEP

TPEP dual anti-corrosion — outer 3PE + inner FBE in one pass

Outer 3PE and inner fusion-bonded epoxy are formed on the same line in one pass — both walls anti-corrosive at once, no separate lining needed; both coatings are inspected together, and adhesion and holiday rate are certified before shipment.

Where it goes: large-diameter water transmission, oilfield gathering, plant process piping; inner FBE is water- and abrasion-resistant for stable water quality, outer 3PE handles the buried environment — DN200–DN3800 fully covered.

Buying tips
1) Prefer TPEP for water projects — one process less than 3PE + mortar lining; 2) inner FBE hygienic data can be supplied to drinking-water requirements; 3) confirm the forming-line diameter limit for large bores first.
ANTI-CORROSION
Anti-corrosion · FBE/2FBE

FBE / 2FBE fusion-bonded epoxy — for hot, harsh service

Epoxy powder is electrostatically sprayed then fusion-cured into a film with strong adhesion and cathodic-disbondment resistance; in two-layer 2FBE the inner coat protects and the outer coat resists abrasion. Service temperature −30 to 110 °C, covering arctic and hot-oil duty, to CAN/CSA Z245.20.

Where it goes: hot-oil lines, desert and arctic pipelines, marine steel piles, station process piping — the first choice where high temperature, a thin coating and cathodic protection must work together.

Buying tips
1) Above 70 °C choose FBE over 3PE; 2) marine piles can take a glass-flake reinforced layer; 3) blast anchor pattern of 60–100 μm is the key to adhesion.
ANTI-CORROSION
Anti-corrosion · Epoxy coal-tar

Epoxy coal-tar anti-corrosion — normal to extra-heavy grade

Epoxy coal-tar paint wrapped with glass cloth — three-oil-two-cloth, four-oil-three-cloth and six-oil-two-cloth give normal, reinforced and extra-heavy grades to SY/T 0447; low cost and proven practice, applied in the plant or on site for field joints and repair.

Where it goes: buried municipal water and sewer networks, fire and heating service pipes, field joints and old-line rehabilitation — the best value for buried projects with tight budgets and moderate duty.

Buying tips
1) Select the grade by burial depth and soil corrosivity — do not cut corners uniformly; 2) use low-temperature-cure type for winter work; 3) accept glass-cloth lap width to code.
ANTI-CORROSION
Anti-corrosion · IPN8710

IPN8710 potable-water coating — hygienic internal protection

IPN8710 interpenetrating-polymer-network paint is non-toxic and odor-free, evaluated for drinking-water hygiene with a sanitary permit; strong adhesion and permanent immersion resistance — suitable for steel-pipe and tank interiors alike.

Where it goes: potable-water pipe interiors, water towers and tanks, pump casings, secondary water-supply facilities; commonly paired with epoxy coal-tar or 3PE externally as a complete outer-plus-inner protection package.

Buying tips
1) Always check the original sanitary permit; 2) coat tanks and pipelines in the same batch for consistency; 3) delivery includes the hygienic test report.
ANTI-CORROSION
Anti-corrosion · Cement-mortar lining

Cement-mortar lining — the classic lining for large water mains

Cement mortar is centrifugally cast onto the interior, separating water from the steel wall — against tuberculation, rust and water-quality drift, to CECS 10 and ISO 4179; the mortar self-heals, and it is the lowest-cost internal protection for large diameters.

Where it goes: large-diameter water transmission mains, water-transfer projects, drainage and pump-station piping — standard above DN800; combined with external 3PE as the classic water-main package.

Buying tips
1) Lining thickness follows the CECS 10 classes by diameter; 2) curing period and joint treatment go into the contract; 3) for large bores prefer centrifugal casting.
ANTI-CORROSION
How it is made

Right process for the right environment

Shot-blasting to Sa2.5, then FBE powder, PE side-extrusion or mortar centrifugal casting — every layer is applied in the same plant and thickness is gauge-checked continuously. Cross-linked processes cover −30 °C arctic service to 110 °C hot oil.

Dedicated anti-corrosion plant with 200,000 ㎡ annual capacity; spiral, ERW and seamless substrates up to DN3800 are all coated in-house, and finished pipes go straight to hydrostatic test and bundling next door.

Buying tips
1) Potable water: ask for the sanitary approval document (GB/T 17219). 2) Fire lines: red coating + pre-fabricated grooves. 3) Mining: require MT 558 dual-resistant certificate and coal-safety (MA) mark.
3PE
Specifications

Anti-corrosion pipe specification

StandardsGB/T 23257 · SY/T 0413 · DIN 30670 · CAN/CSA Z245.20 · SY/T 0447 · CECS 10 · ISO 4179
Applicable diameterDN200 – DN3800(Φ219 – Φ3820 mm)
Processes3PE · 2PE · TPEP · FBE · 2FBE · PEEP · Epoxy coal-tar (normal/heavy/extra-heavy) · IPN8710 · Cement mortar
3PE thicknessNormal ≥ 2.5 mm · reinforced ≥ 2.9 mm · extra ≥ 3.7 mm
Surface preparationShot-blasting to Sa2.5, anchor pattern 60–100 μm
SubstrateSpiral · ERW/JCOE · seamless
Service temperature3PE/TPEP: −30 ~ 70 °C · FBE: −30 ~ 110 °C
InspectionPeel strength · holiday detection (spark) · impact · bending · thickness gauge
Capacity200,000 ㎡

Peel test, holiday detection reports and third-party inspection (SGS / BV / TÜV) available on request.

Applications

Where anti-corrosion pipe is used

Long-distance oil & gas

3PE + PSL2 spiral substrate, 100% NDE, 30-year design life.

Large water transmission

TPEP or 3PE + cement-mortar lining, DN800–DN3800.

Municipal buried networks

Epoxy coal-tar ordinary/heavy grade, budget-friendly.

Hot oil & desert lines

FBE / 2FBE for wide temperature range and strong adhesion.

Potable water & tanks

IPN8710 non-toxic inner coating with hygienic approval.

Field joints & repair

Epoxy coal-tar or heat-shrink systems matched to the line coating.

FAQ

What buyers ask before ordering

3PE vs TPEP — what is the difference?

3PE is an outer-wall three-layer system (FBE + adhesive + PE) protecting against soil and chemicals only; TPEP forms outer 3PE and inner fused epoxy in one pass, so both walls are anti-corrosive at once — used for water and gas transmission.

Epoxy coal-tar or 3PE — how to choose?

Epoxy coal-tar is cheaper, suited to ordinary buried municipal lines and repair joints; 3PE offers higher mechanical strength and 30+ years of life — preferred for long-distance mains, rocky sections and key projects.

IPN8710 vs cement mortar — which inner lining?

IPN8710 is a non-toxic interpenetrating-polymer paint for potable-water pipes and tanks, with sanitary approval; cement-mortar lining suits large-diameter water mains — isolates the medium, prevents tuberculation, low cost, long life.

Workshop · 3PE extrusion and FBE powder line

Replace with our anti-corrosion line: shot-blasting, FBE powder booth, PE side extrusion — 200,000 ㎡ a year.

COATING
COATING

Pre-shipment inspection · Adhesion, flattening and coating thickness

Replace with peel-strength test, spark holiday detection and online thickness gauge.

Project · delivered on site

Replace with a site photo of our anti-corrosion pipe in service — trunk lines, water mains or buried networks.

COATING

Send us the buried environment and diameter

Technical proposal and quotation within one working day.

Request a Quote →
WhatsApp us